0

Total Items 0

  • Email: info@cem-instruments.in
  • Phone: +91-33-22151376 / 22159759

Digital Clamp Meter


Professional Heavy Duty AC, DC/AC T-Rms Auto-Ranging Clamp Meters

DT-3372B

WORK WITH THE BEST

Our new DT-3370 Series Heavy Duty Digital Clamp meters offer all the features you need to fit the way you work. It provides a full range of state of-the-art features to meet even the most demanding job requirements. The body and jaw perfectly fits in your and into tight areas of work. Meter controls are positioned so that current measurements can be done with one hand.

All the three clamp meters have improved based features such as a large, backlit display, true-RMS standards, CAT-IV safety ratings and a durably constructed housing. Have increased reading capability of 1000A and 1000V AC and DC.

These clamp meters confirm to CAT-III 1000V, CAT-IV 600V and are TUV & GS Approved. They confirm to EMC & LVD, EN:61326, EN:61010-1, EN:61010-02-031

add to enquiry Download PDF
  • True RMS Measurements for Accurate AC Voltage and Current Measurements
  • Built-In Non-Contact Voltage Detector
  • Data Hold (all models)
  • Measures Motor Capacitors to 10,000μF
  • 42 mm (2.0") Jaw Opening for Conductors up to 500MCM
  • Rugged Double Molded Housing
  • Autoranging with Manual Override
  • Auto Power Off, Low Battery Indication
  • 41/61 Segment Analogue Bar-Graph
  • Max/Min Record Functions and Relative Measurement functions.
  • Diode and Continuity Check Facility

 

Function Range Resolution Accuracy
DC Current 600A 0.1A ±(2.8%±8Digits)
1000A 1A ±(3.0%±8Digits)

 

Function Range Resolution Accuracy
AC Current   600A 0.1A ±(2.8%±8Digits)
True RMS  
(50 to 60Hz) 1000A 1A ±(3.0%±8Digits)

 

Function Range Resolution Accuracy
DC Voltage 600mV 0.1mV ±(0.8%±2Digits)
6V 0.001V ±(1.5%±2Digits)
60V 0.01V
600V 0.1V
1000V 1V ±(2.0%±2Digits)

 

Input Protection : 1000 V DC.

 

Function Range Resolution Accuracy
AC Voltage   6V 0.001V ±(1.5%±5Digits)
True RMS   60V 0.01V
600V 0.1V
(50Hz to 400Hz) 1000V 1V ±(2.0%±8Digits)

 

Input Protection : 1000V AC RMS.

 

Function Range Resolution Accuracy
Resistance  600Ω 0.1Ω ±(1.0%±4Digits)
6KΩ 0.001KΩ ±(1.5%±2Digits)
60KΩ 0.01KΩ
600KΩ 0.1KΩ
6MΩ 1KΩ ±(2.0%±5Digits)
60MΩ 10KΩ ±(2.5%±5Digits)

 

Input Protection : 250V DC or 250V AC RMS.

 

Function Range Resolution Accuracy
Capacitance 4.000nF 1pF ±(5%±30Digits)
40.00nF 10pF ±(5%±20Digits)
400.0nF 0.1nF ±(3%±5Digits)
4.000uF 1nF
40.00uF 10nF
400.0uF 0.1uF ±(4%±10Digits)
 4.000mF  10uF ±(4.5%±10Digits)

 

Input Protection : 600V DC or 600V AC RMS

 

Function Range Accuracy  (% of reading + digits)
AC Voltage   10HZ-10KHZ (1.0%±5Digits)
Frequency 
(Auto-ranging)

 

Sensitivity : >15V RMS

 

Frequency with Jaws ( AC Current)

 

Function Range Resolution Accuracy
Hz 100Hz~ 0.1 ±(1.0%±5Digits)

 

Sensitivity : >50 A (600A) > 500A (1000A)

 

Function Range Resolution Accuracy
Frequency 9.999Hz 0.001Hz ±(1%±5Digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
999.9kHz 100Hz
10MHz 10kHz

 

Sensitivity : >5V RMS

 

 

Function Range Resolution Accuracy
Temperature (Type-k) (probe accuracy not included) -20to 0.1°C ±(3%±5Digits)
-4to1400°C 0.1°F

 

 

 

Input Protection : 600V DC or 600V AC RMS

 

 

Function Testing Condition Reading
Diode  Forward DCA is approx .1mA, open circuit Voltage  Forward voltage drop of Diode
MAX.1.5V
Continuity Test current   Buzzer makes a long sound, While resistance is lessthan(35Ω)
MAX.1.5mA

 


Input Protection : 600V DC or 600 V AC RMS 

 

Function Range Resolution Accuracy
Duty Cycle 5to  0.10% ±(1.0%±2Digits)
  • Testing Leads
  • Soft Carrying Case
  • Instruction Manual
  • Temperature Probe
  • Battery