0

Total Items 0

  • Email: info@cem-instruments.in
  • Phone: +91-33-22151376 / 22159759

Digital Clamp Meter


Industrial Use Rugged AC and DC/AC T-Rms Clamp Meters

DT-3390

Confidently take reliable readings with the DT-3390/DT-3391/DT-3395 Series of clamp meters. The Extra Wide Jaw easily clamps around large conductors, typically found in high current applications. The rugged design CAT-IV 600V, CAT-III 1000V ratings add an extra element of protection when taking high-powered measurements. The measurement of capacitance, temperature (not available in DT-3390), resistance and Frequency makes these this the most versatile tool for utilities, electrical contractors and industrial service technicians.

add to enquiry Download PDF
  • Large Backlit Display of 3999 Counts
  • Built-In Non-Contact Voltage Detector
  • Electronic Overload Protection
  • Continuity & Diode Test
  • Auto Power Off & Data Hold
  • Low Battery Indication
  • Capacitance Measurement of up to 100uF
  • 52mm Clamp Jaw Opening for Conductors up to 600MCM

 

General Specifications

Clamp size  Opening 2"(52mm) approx.
Diode Test  Test current of 0.3mA typical; Open circuit voltage 1.SV DC typical
Continuity Check  Threshold < 150Ω; Test current <0.5mA
Over range Indication “OL” is displayed
Relative Measurement  Helps to measure any parameter with respect with a set value
Data Hold  Freezes Displayed Data
Measurements Rate  2 per second, nominal
Input Impedance  10M Ω (VDC and VAC)
Display  3 -  3 / 4 Digits 4000 counts Backlit LCD
AC Current 50 - 60Hz (AAC)
AC Voltage Bandwidth  50 - 400Hz (VAC)
Operating Temperature  5 to 40°C (41 to 104°F)
Storage Temperature  -20 to 60°C (-4 to 140°F)
Operating Humidity  Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity  <80%
Operating Altitude  7000ft. (2000meters) maximum
Battery  One 9V Battery
Auto Power Off  approx. 30 minutes
Dimensions/Weight  270 x 100 x 47mm; 450g
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category Ill 1000V and Category IV 600/, Pollution Degree 2

 

 

Electrical Specifications

Function  Range & Application Accuracy (% of reading)
AC Current (50/60Hz) 40.00 AAC  ±(2.2% + 12 digits)
400.0 AAC ±(2.5% + 5 digits)
1000 AAC
DC Voltage 400.0 mVDC ±(0.8% + 2 digits)
4.000 VDC ±(1.5% + 2 digits) 
40.00 VDC
400.0 VDC
1000 VDC ±(2% + 4 digits)
ACVoltage 4.000 VAC ±(1.5% + 8 digits) 
40.00 VAC
400.0 VAC
1000 VAC  ±(2% + 4 digits)
Resistance 400.0Ω  ±(1.0% + 4 digits)
4.000KΩ
40.00KΩ
400.0KΩ
4.000MΩ ±(2.5% + 3 digits)
40.00MΩ ±(3.5% + 5 digits)
Capacitance 40.00nF  ±(5.0% reading + 30 digits)
400.0nF  ±(3.0% reading + 5 digits)
4.000mF ±(3.5% reading + 5 digits)
40.00mF
100.0mF  ±(5.0% reading + 5 digits)
Frequency Sensitivity : >5V RMS (5Hz tD 1OMHz) 9.999Hz ±(1.5% of reading ± 5 digits)
99.99Hz
999.9Hz ±1.2% of reading ± 3 digits
9.999kHz
99.99kHz
999.9kHz
9.99MHz  ±1.5% of reading ± 4 digits
Duty Cycle Sensitivity : >5V RMS, Pulse width: >100uS, <100ms 0.1% - 99.9%  ±1.2% of reading ± 2 digits

 


Accuracy is stated at 18°C to 28°C (65°F to 83°F) and less than 75%RH

 

  • Carrying Case
  • Testing Leads
  • Instruction Manual
  • Battery
  • Test Certificate