Digital Clamp Meter


Professional AC, DC/AC T-RMS Auto-Ranging

DT-356

Our new family of true-RMS clamp meters provides a range of state of-the-art features to meet even the most demanding job requirements. All four of the new clamp meters have improved base features such as a large, backlit display, true-RMS standard, CAT IV safety rating and a durably constructed body. These have small bodies and jaw design for perfectly fitting in hand and in tight areas. The Backlit Display helps in working in dark areas.

 

  • 3-5/6 Digits 6000 Counts Backlit LCD with Bargraph
  • Fully Overload Protection
  • Non Contact Voltage Detector to indicate Live Wire
  • 1000V DC/AC Protection in Frequency, Temperature, Resistance, Capacitance, Diode & Continuity Test
  • Data Hold Freezes the display
  • MAX / MIN record and Relative measurement
  • AC-TRMS / DC Current up to 1000A
  • AC-TRMS / DC Voltage up to 600V
  • Motor Capacitors up to 4000uF can be measured
  • Temperature and Frequency Measurement
  • 40mm Clamp Jaw Dia
  • AC Current and AC Voltage Bandwidth 50 ~ 400Hz
  • Continuity and Diode Test
  • Auto Power Off after 15 mins.
  • Over-range and Low Battery Indication
  • 9V Battery Operated
  • Operating Temperature: 5 to 40°C (41°F to 104°F)
  • Storage Temperature: -20 to 60°C (-4°F to 140°F)
  • Operating Humidity: Max 80% up to 31°C decreasing linearly to 50% at 40°C
  • Storage Humidity < 80% RH
  • Operating Altitude 7000 ft
  • 9V Battery Operated

 

Function  Range  Resolution  Accuracy
AC Current True RMS (50 to 60Hz) 600A 0.1A ± (2.8 % ± 8 Digits)
1000A 1A ± (3.0 % ± 8 Digits)

 

Function  Range  Resolution  Accuracy
AC Current True RMS (400Hz) 600A 0.1A ± (5 % ± 10 Digits)
1000A 1A

 

Function  Range  Resolution  Accuracy
DC Current 600A 0.1A ± (2.8 % ± 5 Digits)
1000A 1A ± (3.0 % ± 5 Digits)

 

Function  Range  Resolution  Accuracy
DC Voltage 600mV 0.1mV ± (1.5 % ± 2 Digits)
6V 0.001V
60V 0.01V
600V 0.1V

Input Protection: 1000V DC.

 

Function  Range  Resolution  Accuracy
AC Voltage
True RMS
(50Hz to 400Hz)
6V 0.001V ± (1.8 % ± 8 Digits)
60V 0.01V
600V 0.1V

Input Protection: 1000V AC RMS.

 

 

Function  Range  Resolution  Accuracy
Resistance 600Ω 0.1Ω ± (1.0 % ± 4 Digits)
6 KΩ 0.001 KΩ ± (1.5 % ± 2 Digits)
60 KΩ 0.01 KΩ
600 KΩ 0.1 KΩ
6 MΩ 1 KΩ ± (2.5 % ± 3 Digits)
60 MΩ 1 10 KΩ ± (3.5 % ± 5 Digits)

Input Protection: 1000V DC or 1000V AC RMS.

 

 

Function  Range  Resolution  Accuracy
Capacitance 40.00nF 10pF ± (4.0 % ± 20 Digits)
400.0nF 0.1nF ± (3.0 % ± 5 Digits)
4.000uF  1nF
40.00uF 10nF
400.0uF 0.1uF ± (4 % ± 10 Digits)
4000uF 1uF ± (5 % ± 10 Digits)

Input Protection: 1000V DC or 1000V AC RMS.

 

 

Function  Range  Resolution  Accuracy
Frequency 9.999Hz 0.001Hz ± (1.5 % ± 2 Digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz

Sensitivity: >5V RMS (5Hz to 10MHz)

 

Function  Range  Resolution  Accuracy
Duty Cyle 0.1% - 99.9% 0.1% ± (1.2 % ± 2 Digits)

 

 

Function  Range  Resolution  Accuracy
Temperature (type-K) (probe accuracy not included) -20 to 760°C 0.1°C ± (3 % ± 5 Digits)
± (3 % ± 5 Digits) 0.1°F ± (3 % ± 9 Digits)

Input Protection: 1000V DC or 1000V AC RMS.

 

 

Function Testing Condition Reading
Diode Forward DCA is approx.0.3mA, open circuit Voltage MAX . 1.5V Forward voltage drop of Diode
Continuity Test current MAX. 0.5mA Buzzer makes a long sound, While resistance is less than (40W)

Input Protection: 1000V DC or 1000V AC RMS.

 

  • Carrying Case
  • Testing Leads
  • Temperature Probe
  • Test Report
  • Instruction Manual
  • Battery