The 175/176 is a datalogger for measuring and recording True RMS current and voltage. The readings are saved in the logger and simply read out by your PC with USB interface. The LCD can show current readings, MAX, MIN and sign of alarm.
Input Channel | Dual |
T-RMS Measurement | ● |
Data Memory | 200000 |
Wave Memory | ● |
MAX/MIN, Peak Mode | ● |
Time & Date Stamp | ● |
Wave store | ● |
Auto Power Off | ● |
USB Interface | ● |
Manual & Automatic Mode | ● |
Function | Range | Accuracy |
AC Current (True RMS) | 200A | ±2% |
AC Voltage (True RMS) | 600V | ±1.5% |
Measuring rate | 1 sec. to 24h | |
Analysis software | Windows 7/8/98/2000/XP | |
size(HxWxD) | 114mm x 63mm x 34mm | |
weight: | 248g |
Function | Range | Basic Accuracy |
Voltage (40Hz to 1kHz) | 10V to 600.0VAC | ± 2.0% r± 1 V |
Current (50/60Hz) | 10A to 200.0A | ± 2.0% r± 1 A |
Display | Multi-function LCD |
Maximum Data Point | 256,000 Values |
Channels | Dual Channel, TRMS AC Voltage or Current |
Sample Rate | 1s to 24h Selectable |
Analysis Software | 2000 / XP / Vista /Windows 7 & 8 |
Data Output | USB Port |
Current Clamp Jaw Opening | 0.5” (12.7mm) |
Open input indication | “LO” Appears on the LCD |
Low Battery Indication | Battery Symbol Appears on the LCD |
Power Supply | 4AAA Batteries and 1CR 3V memory Button Battery (Cr2032 or Equivalent) |
Battery Life | 5 Days (Appoximately) |
AC Adaptor | 9V, 0.5A |
Standards | CE, CAT III 600V, for inside use, Maximum height 2000 meters |
Operating Temperature | 0°C to 50°C, -32°F to 122°F |
Operating Humidity | < 70% RH |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Storage Humidity | < 80% Relative Humidity |
Dimensions | 4.5 x 2.5 x 1.3” (114 x 63 x 34mm) |
Weight | 8.70z. (248g) |