The DT-9660 series of Multimeters are compact, easy-to-use tools that deliver, safe, reliable measurements. These are completely protected against wrong connections and confirm to EN-61010-1, CAT-IV 600V and CAT-III 1000V. The IP-67 protection makes the instrument dust proof and water proof, hence they can by used in any environment. These meters have 10A/1000V & 0.5A/1000V Fuse protection on current range. Your job requires that you have a rugged, reliable and accurate digital multimeter. The DT-9960 series offer everything you need.
DC Voltage (Auto-ranging)
Range | Resolution | Accuracy |
400.0mV | 0.1mV | ±1.2% of rdg ± 2 digits |
4.000V | 1mV | |
40.00V | 10mV | |
400.0V | 100mV | |
1000V | 1V | ±1.5% of rdg ± 2 digits |
Input Impedance: 10MΩ
Maximum Input: 1000V DC or 1000V AC RMS.
AC Voltage(T-RMS) (Auto-ranging)
Range | Resolution | Accuracy |
400.0mV | 0.1mV | ±1.5%of rdg ±8 digits |
4.000V | 1 mV | ±1.5%of rdg ±3 digits |
40.00V | 10mV | |
400.0V | 100mV | |
1000V | 1V | ±1.5%of rdg ± 5 digits |
Input Impedance: 10MΩ.
AC Response: 50 Hz to 400Hz
Maximum Input: 1000V DC or 1000V AC RMS
DC Current (Auto-ranging)
Range | Resolution | Accuracy |
400.0uA | 0.1 uA | ±1.2% of rdg ± 5 digits |
4000uA | 1uA | |
40.00mA | 10 uA | |
400.0mA | 100uA | |
10A | 10mA | ±1.5% of rdg ± 5 digits |
Overload Protection : FF500mA / 1000V and F10A / 1000V Fuse.
Maximum Input: 400uA DC on uA range 400mA DC on mA range 10A DC on 10A range
AC Current(T-RMS) (Auto-ranging)
Range | Resolution | Accuracy |
400.0uA | 0.1uA | ±1.5% of rdg ± 5 digits |
4000uA | 1uA | |
40.00mA | 10uA | |
400.0mA | 100 uA | |
10A | 10mA | ±1.8% of rdg ± 5 digits |
Overload Protection : FF500mA / 1000V and F10A / 1000V Fuse
AC Response: 50 Hz to 400 Hz
Maximum Input: 4400uA AC RMS on uA 400mA AC RMS on mA 10A AC RMS on 10A range
Resistance (Ω) (Auto-ranging)
Range | Resolution | Accuracy |
400.0Ω | 0.1Ω | ±1.2% of rdg ± 5 digits |
4.000kΩ | 1Ω | ±1.2% of rdg ± 2 digits |
40.00kΩ | 10Ω | |
400.0kΩ | 100Ω | |
4.000MΩ | 1kΩ | ±2.5% of rdg ± 8digits |
40.00MΩ | 10kΩ |
Input Protection: 1000V DC or 1000V AC RMS.
Capacitance (Auto-ranging)
Range | Resolution | Accuracy |
40.00nF | 10pF | ±5.0% of rdg ± 7 dgts |
400.0nF | 0.1 nF | ±3.0% of rdg ± 5 dgts |
4.000uF | 1nF | |
40.00uF | 10 nF | |
400.0uF | 0.1uF | |
4.000mF | 1uF | ±5.0% of rdg ± 7 dgts |
40.00mF | 10uF |
Input Protection: 1000V DC or 1000V AC RMS
Frequency (Auto-ranging)
Range | Resolution | Accuracy |
4.000KHz | 1 Hz | ±1.0 % of rdg ± 3 dgts |
40.00kHz | 10 Hz | |
400.0kHz | 100 Hz | |
10.00MHz | 1kHz | ±1.2% of rdg ± 4 dgts |
Sensitivity : >0.5V RMS while ≤1MHz ;
Sensitivity : >3V RMS while >1MHz ;
Input Protection : 1000V DC or 1000V AC RMS.
Duty Cycle
Range | Resolution | Accuracy |
0.1%~99.9% | 0.1% | ±1.2% of rdg ± 2 dgts |
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150kHz
Sensitivity: <0.5V RMS
Overload protection: 1000V DC OR AC RMS.
Temperature
Range | Resolution | Accuracy |
-20°C~+760°C | 1°C | ±3% of rdg ± 5 dgts |
-4°F~+1400°F | 1°F | ±3% of rdg ± 8dgts |
Sensor: Type K Thermocouple
Overload protection: 1000V DC or AC RMS.
Diode Test
Test current | Resolution | Accuracy |
1Matypical / Open MAX.3V | 1 mV | ±10% of rdg ± 5 digits |
Open circuit voltage: MAX. 3V dc
Overload protection: 1000V DC or AC RMS.
Audible continuity
Audible threshold : Less than35Ω Test current MAX. 1.5mA
Overload protection : 1000V DC or AC RMS.