BE READY FOR ANYTHING
The DT-3380 Series of Digital Clamp meters offers all the specifications required by any field engineer working on-site at incoming power site. These are very elegantly designed, perfectly fit into hand and can be used to access tight places for testing. The large backlit LCD with high display count of 50,000 provides precise and accurate readings with details till the last digit. The bright backlit and bright flashlight in the clamp, makes it easier to use in dark areas.
These clamp meters confirm to CAT-III 1000V, CAT-IV 600V and are TUV & GS Approved. They confirm to EMC & LVD, EN:61326, EN:61010-1, EN:61010-02-031
The dual input thermometer with K type inputs for temperature, with differential temperature function, makes it all the more useful for all field use.
Function | Range | Resolution | Accuracy |
DC Current | 50A | 0.01A | ± (2.5 % ± 5 Digits) |
1000A | 0.1A |
Function | Range | Resolution | Accuracy |
AC uA Current | 500uA | 0.01uA | ± (1.5 % ± 30 Digits) |
5000uA | 0.1uA |
Function | Range | Resolution | Accuracy |
AC Current True RMS (50 to 60Hz) | 50A | 0.01A | ± (2.5 % ± 5 Digits) |
1000A | 0.1A |
Function | Range | Resolution | Accuracy |
DC uA Current | 500uA | 0.01uA | ± (1.0 % ± 6 Digits) |
5000uA | 0.1uA |
Function | Range | Resolution | Accuracy |
DC Voltage | 500mV | 0.01mV | ± (1.0 % ± 8 Digits) |
5V | 0.0001V | ± (0.1 % ± 4 Digits) | |
50V | 0.001V | ||
500V | 0.01V | ||
600V | 0.1V |
Function | Range | Resolution | Accuracy |
AC Voltage True RMS (50Hz to 1000Hz) | 500mV | 0.01mV | ± (1.0 % ± 30 Digits) |
5V | 0.0001V | ||
50V | 0.001V | ||
500V | 0.01V | ||
600V | 0.1V |
All AC Voltage Range are specifed from 5% of range to 100% of range
Function | Range | Resolution | Accuracy |
Resistance | 500Ω | 0.01Ω | ± (1.0 % ± 9 Digits) |
5 KΩ | 0.0001 KΩ | ± (1.0 % ± 5 Digits) | |
50 KΩ | 0.001 KΩ | ||
500 KΩ | 0.01 KΩ | ||
5 MΩ | 0.1 KΩ | ± (2.0 % ± 10 Digits) | |
50 MΩ | 1 KΩ | ± (3.0 % ± 10 Digits) |
Function | Range | Resolution | Accuracy |
Capacitance | 500nF | 0.01nF | ± (3.5 % ± 40 Digits) |
5000nF | 0.1nF | ± (3.5 % ± 10 Digits) | |
50uF | 0.01uF | ||
500uF | 0.1uF | ||
5mF | 0.001mF | ± (5 % ± 10 Digits) |
Function | Range | Resolution | Accuracy |
Frequency | 50Hz | ± (0.3 % ± 2 Digits) | |
500Hz | |||
5kHz | |||
50kHz | |||
500kHz | |||
5MHz | |||
10MHz |
Function | Range | Resolution | Accuracy |
Duty Cycle | 5 to 95% | 0.001 | ± (1.0 % ± 2 Digits) |
Pulse Width: 100uS - 100mS, Frequeny: 10Hz to 10kHz
Function | Range | Resolution | Accuracy |
Temperature | -100 to 1000°C | 0.1°C | ± (1.0 % ± 2.5°C) |
(type-K) (probe accuracy not included) | -148 to 1832°F | 0.1°F | ± (1.0 % ± 4.5°F) |