Our new family of true-RMS clamp meters provides a range of state of-the-art features to meet even the most demanding job requirements. All four of the new clamp meters have improved base features such as a large, backlit display, true-RMS standard, CAT IV safety rating and a durably constructed body. These have small bodies and jaw design for perfectly fitting in hand and in tight areas. The Backlit Display helps in working in dark areas.
Input Limits | |
Function | Maximum Input |
A AC | 1000A |
V DC, V AC | 1000V DC/AC |
Frequency, Resistance, Diode, Continuity, Capacitance Test | 1000V DC/AC |
Temperature (°C/°F) | 1000V DC/ AC |
Electrical Specifications
Function | Range & Resolution | Accuracy (% of reading) |
AC Current (50/60Hz) | 600.0 AAC | ± (2.8 % + 8 digits) |
1000 AAC | ± (3.0 % + 8 digits) | |
AC Current (400Hz) | 600.0 AAC | ± (5.0 % + 10 digits) |
1000 AAC | ± (5.0 % + 10 digits) | |
DC Voltage | 600.0 mVDC | ± (0.8% + 2 digits) |
6.000 VDC | ± (1.5% + 2 digits) | |
60.00 VDC | ||
600.0 VDC | ||
AC Voltage (50-400Hz) | 6.000 VAC | ± (1.8% + 8 digits) |
60.00 VAC | ||
600.0 VAC | ||
Resistance | 600.0Ω | ± (1.0% + 4 digits) |
6.000KΩ | ± (1.5% + 2 digits) | |
60.00KΩ | ||
600.0KΩ | ||
6.000MΩ | ± (2.5% + 3 digits) | |
60.00MΩ | ± (3.5% + 5 digits) | |
Capacitance | 40.00nF | ± (4.0% reading + 20 digits) |
400.0nF | ± (3% reading + 5 digits) | |
4.000μF | ||
40.00μF | ||
400.0μF | ± (4.0% reading + 10 digits) | |
4000μF | ± (5.0% reading + 10 digits) | |
Frequency Sensitivity: 15Vrms | 10-10kHz | ± (1.5% reading + 2 digits) |
Temperature (type-K) (probe accuracy not included) | -20.0 to 760.0°C | ± (3%rdg + 5°C) |
-4.0 to 1400.0°F | ± (3%rdg + 9°F) |
General Specifications
Clamp size | Opening 1.5” (40mm) approx |
Diode Test | Test current of 0.3mA typical; Open circuit voltage 1.5V DC typical |
Continuity Check | Threshold <40 |
Max./Min. | Records maximum and minimum data |
Data Hold | Freezes the displayed data |
Relative Measurement | allows reading with respect to a defined values |
Test current < 0.5mA | Two “1.5V” batteries |
Overrange Indication | “OL” is displayed |
Measurements Rate | 2 per second, nominal |
Input Impedance | 10MΩ (VDC and VAC) |
Display | 6000 counts Backlit LCD with Analogue Bargraph |
AC Current | 50-400Hz (AAC) |
AC Voltage bandwidth | 50-400Hz (VAC) |
Operating Temperature | 41 to 104°F (5 to 40°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
Storage Humidity | <80% |
Operating Altitude (2000meters)maximum | 7000ft. |
Over voltage | Category III 600V |
Battery | One 9V Battery |
Auto Power Off | approx. 15 minutes |
Dimensions/Weight | 232 x 77 x 39mm/271g |
Safety | For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Cat. III |